This is the documentation for the latest (main) development branch of Zephyr. If you are looking for the documentation of previous releases, use the drop-down menu on the left and select the desired version.

st,iis2iclx (on spi bus)

Vendor: STMicroelectronics

Description

STMicroelectronics IIS2ICLX 2-axis accelerometer sensor
accessed through SPI bus

Properties

Properties not inherited from the base binding file.

Name

Type

Details

spi-max-frequency

int

Maximum clock frequency of device's SPI interface in Hz

This property is required.

supply-gpios

phandle-array

GPIO specifier that controls power to the device.

This property should be provided when the device has a dedicated
switch that controls power to the device.  The supply state is
entirely the responsibility of the device driver.

Contrast with vin-supply.

vin-supply

phandle

Reference to the regulator that controls power to the device.
The referenced devicetree node must have a regulator compatible.

This property should be provided when device power is supplied
by a shared regulator.  The supply state is dependent on the
request status of all devices fed by the regulator.

Contrast with supply-gpios.  If both properties are provided
then the regulator must be requested before the supply GPIOS is
set to an active state, and the supply GPIOS must be set to an
inactive state before releasing the regulator.

drdy-gpios

phandle-array

DRDY pin
This pin defaults to active high when produced by the sensor. The property value should ensure the flags properly describe the signal that is presented to the driver.

int-pin

int

Select DRDY pin number (1 or 2).
This number represents which of the two interrupt pins (INT1 or INT2) the drdy line is attached to. This property is not mandatory and if not present it defaults to 1 which is the configuration at power-up.

Default value: 1

Legal values: 1, 2

range

int

Range in g. Default is power-up configuration.

Default value: 3

Legal values: 0, 1, 2, 3

odr

int

Specify the default accelerometer output data rate expressed in samples per second (Hz). Default is power-up configuration.

Legal values: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10